Acceleration - Speed - Vibration Calibration Services
Centrifuges, RPM Sources, Mixers, Stroboscopes, Tachometers (Contact & Non-Contact: 6 to 99999 RPM), Vibration Machines, Shakers, Portable Calibrators & Vibration Meters/Sensors (Displacement, Velocity, Acceleration @ 10 Hz to 1280 Hz).
Instruments & Parameters Covered (38)
Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).
| Instrument / Parameter | Calibration Range | CMC (±) | Master / Method |
|---|---|---|---|
| Centrifuge [Permanent] (> 10000 RPM to 50000 RPM) | > 10000 RPM to 50000 RPM | 3 RPM | Using Digital Tachometer by Comparison Method |
| Centrifuge [Permanent] (> 50000 RPM to 99999 RPM) | > 50000 RPM to 99999 RPM | 3.42 RPM | Using Digital Tachometer by Comparison Method |
| Centrifuge [Permanent] (> 60 RPM to 10000 RPM) | > 60 RPM to 10000 RPM | 1.6 RPM | Using Digital Tachometer by Comparison Method |
| Centrifuge [Permanent] (15 RPM to 60 RPM) | 15 RPM to 60 RPM | 1.6 RPM | Using Digital Tachometer by Comparison Method |
| RPM Source [Permanent] (> 100 RPM to 9999 RPM) | > 100 RPM to 9999 RPM | 1.4 RPM | Using Digital Tachometer by Comparison Method |
| RPM Source [Permanent] (20 RPM to 100 RPM) | 20 RPM to 100 RPM | 0.41 RPM | Using Digital Tachometer by Comparison Method |
| Stroboscope [Permanent] (> 10000 RPM to 50000 RPM) | > 10000 RPM to 50000 RPM | 2.79 RPM | Using Digital Tachometer by Comparison Method |
| Stroboscope [Permanent] (> 50000 RPM to 99999 RPM) | > 50000 RPM to 99999 RPM | 3.42 RPM | Using Digital Tachometer by Comparison Method |
| Stroboscope [Permanent] (> 60 RPM to 10000 RPM) | > 60 RPM to 10000 RPM | 1.63 RPM | Using Digital Tachometer by Comparison Method |
| Stroboscope [Permanent] (15 RPM to 60 RPM) | 15 RPM to 60 RPM | 0.3 RPM | Using Digital Tachometer by Comparison Method |
| Tachometer [Permanent] (> 100 RPM to 15000 RPM) | > 100 RPM to 15000 RPM | 1.3 RPM | Using Digital Tachometer and RPM Source by Comparison Method |
| Tachometer [Permanent] (6 RPM to 100 RPM) | 6 RPM to 100 RPM | 0.41 RPM | Using Digital Tachometer and RPM Source by Comparison Method |
| Tachometer [Permanent] (> 10000 RPM to 50000 RPM) | > 10000 RPM to 50000 RPM | 2.79 RPM | Using Digital Tachometer and RPM Source by Comparison Method |
| Tachometer [Permanent] (> 50000 RPM to 99999 RPM) | > 50000 RPM to 99999 RPM | 3.42 RPM | Using Digital Tachometer and RPM Source by Comparison Method |
| Tachometer [Permanent] (> 60 RPM to 10000 RPM) | > 60 RPM to 10000 RPM | 1.63 RPM | Using Digital Tachometer and RPM Source by Comparison Method |
| Tachometer [Permanent] (6 RPM to 60 RPM) | 6 RPM to 60 RPM | 0.3 RPM | Using Digital Tachometer and RPM Source by Comparison Method |
| Vibration Machine [Permanent] (0.5 m/s² to 199.9 m/s²) | 0.5 m/s² to 199.9 m/s² | 2.5 % | Using Accelerometer with Signal Analyser & Precision Multimeter by Comparison Method |
| Vibration Machine [Permanent] (0.014 mm to 1.999 mm) | 0.014 mm to 1.999 mm | 2.5 % | Using Accelerometer with Signal Analyser & Precision Multimeter by Comparison Method |
| Vibration Machine [Permanent] (0.5 mm/s to 199.9 mm/s) | 0.5 mm/s to 199.9 mm/s | 2.5 % | Using Accelerometer with Signal Analyser & Precision Multimeter by Comparison Method |
| Vibration Meter [Permanent] (0.014 mm to 1.999 mm) | 0.014 mm to 1.999 mm | 2.4 % | Using Vibration Calibration Reference System, Vibration Meter & Precision Multimeter by Comparison Method as per ISO 16063 |
| Vibration Meter [Permanent] (1 mm/s to 199.9 mm/s) | 1 mm/s to 199.9 mm/s | 2.4 % | Using Vibration Calibration Reference System, Vibration Meter & Precision Multimeter by Comparison Method as per ISO 16063 |
| Vibration Meter [Permanent] (0.5 m/s² to 199.9 m/s²) | 0.5 m/s² to 199.9 m/s² | 2.5 % | Using Vibration Calibration Reference System, Vibration Meter & Precision Multimeter by Comparison Method as per ISO 16063 |
| Centrifuge [Site] (> 10000 RPM to 50000 RPM) | > 10000 RPM to 50000 RPM | 3 RPM | Using Digital Tachometer by Comparison Method |
| Centrifuge [Site] (> 50000 RPM to 99999 RPM) | > 50000 RPM to 99999 RPM | 3.42 RPM | Using Digital Tachometer by Comparison Method |
| Centrifuge [Site] (> 60 RPM to 10000 RPM) | > 60 RPM to 10000 RPM | 1.6 RPM | Using Digital Tachometer by Comparison Method |
Frequently Asked Questions
Are Acceleration - Speed - Vibration calibrations NABL accredited?
Yes. Our Acceleration - Speed - Vibration laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.
Do you offer on-site Acceleration - Speed - Vibration calibration at client plants?
Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Acceleration - Speed - Vibration calibration, minimizing equipment downtime.
What is the standard turnaround time for calibration certificates?
Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.
How do I request a quotation for Acceleration - Speed - Vibration?
Click the "Request a Quote" button on this page to pre-select Acceleration - Speed - Vibration, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.