Energy - Gauss - pH - Conductivity Calibration Services
1-Phase & 3-Phase Energy Meters, Active Power, Power Factor, Phase Angle, Gauss Meters (Magnetic Flux), pH Meters, and Conductivity Meters.
Instruments & Parameters Covered (39)
Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).
| Instrument / Parameter | Calibration Range | CMC (±) | Master / Method |
|---|---|---|---|
| 1 Phase 2 Wire AC Active Energy (0.05 A to 10 A) [Permanent] | 0.64 Wh to 2.4 kWh | 0.21 % to 0.19 % | 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A) |
| 1 Phase 2 Wire AC Active Energy (10 A to 20 A) [Permanent] | 0.127 kWh to 4.8 kWh | 0.19 % to 0.16 % | 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A) |
| 1 Phase 2 Wire AC Active Power (PF: 0.2 Lead / Lag) [Permanent] | 2.4 W to 960 W | 1.2 % | 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.2 (lead / lag), 120 V to 240 V, 0.1 A to 20 A) |
| 1 Phase 2 Wire AC Active Power (PF: 0.5 Lead / Lag) [Permanent] | 6 W to 2.4 kW | 0.37 % | 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.5 (lead / lag), 120 V to 240 V, 0.1 A to 20 A) |
| 1 Phase 2 Wire AC Active Power (PF: 0.8 Lead / Lag) [Permanent] | 9.6 W to 3.8 kW | 0.18 % | 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.8 (lead / lag), 120 V to 240 V, 0.1 A to 20 A) |
| 1 Phase 2 Wire AC Active Power (UPF) [Permanent] | 1.2 W to 4.8 kW | 0.13 % | 1 Phase 2 Wire, AC Active Power @ (50 Hz, 120 V to 240 V, 0.01 A to 20 A, UPF) |
| 1 Phase 2 Wire AC Power Factor [Permanent] | 0.2 (lead / Lag) to UPF | 0.002 PF to 0.001 PF | 1 Phase 2 Wire, AC Power Factor @ (50 Hz, 120 V to 240 V, 0.1 A to 20 A) |
| 1 Phase 2 Wire Phase Angle [Permanent] | 0° to 360° | 0.008° | 1 Phase 2 Wire, Phase Angle @ (50 Hz, 120 V to 240 V, 0.1 A to 20 A) |
| 3 Phase 3 Wire AC Active Energy (0.05 A to 10 A) [Permanent] | 1.10 Wh to 4.16 kWh | 0.21 % to 0.19 % | 3 Phase 3 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A) |
| 3 Phase 4 Wire AC Active Energy (0.05 A to 10 A) [Permanent] | 1.10 Wh to 4.16 kWh | 0.21 % to 0.19 % | 3 Phase 4 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A) |
| 3 Phase 3 Wire AC Active Energy (10 A to 20 A) [Permanent] | 0.219 kWh to 8.31 kWh | 0.19 % to 0.16 % | 3 Phase 3 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A) |
| 3 Phase 4 Wire AC Active Energy (10 A to 20 A) [Permanent] | 0.219 kWh to 8.31 kWh | 0.19 % to 0.16 % | 3 Phase 4 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A) |
| 3 Phase 3 Wire AC Active Power [Permanent] | 1.09 W to 8.31 kW | 0.13 % to 0.25 % | 3 Phase 3 Wire, AC Active Power @ (50 Hz, 0.2 lead / Lag to UPF, 63.5 V to 240 V, 0.05 A to 20 A) |
| 3 Phase 4 Wire AC Active Power [Permanent] | 1.09 W to 8.31 kW | 0.13 % to 0.25 % | 3 Phase 4 Wire, AC Active Power @ (50 Hz, 0.2 lead / Lag to UPF, 63.5 V to 240 V, 0.05 A to 20 A) |
| 3 Phase 3 Wire AC Power Factor [Permanent] | 0.2 (lead / Lag) to UPF | 0.004 PF | 3 Phase 3 Wire, AC Power Factor @ (50 Hz, 240 V, 1 A to 5 A) |
| 3 Phase 4 Wire AC Power Factor [Permanent] | 0.2 (lead / Lag) to UPF | 0.004 PF | 3 Phase 4 Wire, AC Power Factor @ (50 Hz, 240 V, 1 A to 5 A) |
| 3 Phase 3 Wire Phase Angle [Permanent] | 0° to 360° | 0.006° | 3 Phase 3 Wire, Phase Angle @ (50 Hz, 240 V, 1 A to 5 A) |
| 3 Phase 4 Wire Phase Angle [Permanent] | 0° to 360° | 0.006° | 3 Phase 4 Wire, Phase Angle @ (50 Hz, 240 V, 1 A to 5 A) |
| Conductivity Meter (0.1 µS to 475 mS) [Permanent] | 20 ohm to 10 Mohm (0.1 µS to 475 mS) | 1.61 % to 7.86 % | Conductivity Meter - (0.1 µS to 475 mS) |
| Gauss Meter / Magnetometer [Permanent] | 2.5 Gauss to 10000 Gauss | 6.6 % | Gauss Meter |
| pH Meter (0 to 20 pH) [Permanent] | (-)440 mV to 440 mV (0 to 20 pH) | 0.057 % | pH Meter - (0 to 20 pH) |
| 1 Phase 2 Wire AC Active Energy (0.05 A to 10 A) [On-Site] | 0.64 Wh to 2.4 kWh | 0.21 % to 0.19 % | 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A) |
| 1 Phase 2 Wire AC Active Energy (10 A to 20 A) [On-Site] | 0.127 kWh to 4.8 kWh | 0.19 % to 0.16 % | 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A) |
| 1 Phase 2 Wire AC Active Power (PF: 0.2 Lead / Lag) [On-Site] | 2.4 W to 960 W | 1.2 % | 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.2 (lead / lag), 120 V to 240 V, 0.1 A to 20 A) |
| 1 Phase 2 Wire AC Active Power (PF: 0.5 Lead / Lag) [On-Site] | 6 W to 2.4 kW | 0.37 % | 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.5 (lead / lag), 120 V to 240 V, 0.1 A to 20 A) |
Frequently Asked Questions
Are Energy - Gauss - pH - Conductivity calibrations NABL accredited?
Yes. Our Energy - Gauss - pH - Conductivity laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.
Do you offer on-site Energy - Gauss - pH - Conductivity calibration at client plants?
Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Energy - Gauss - pH - Conductivity calibration, minimizing equipment downtime.
What is the standard turnaround time for calibration certificates?
Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.
How do I request a quotation for Energy - Gauss - pH - Conductivity?
Click the "Request a Quote" button on this page to pre-select Energy - Gauss - pH - Conductivity, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.