Skip to main content
NABL Accredited ISO/IEC 17025:2017 • CC-4178 Permanent Lab Calibration + On-Site Field Calibration 2 Scopes (10 Instrument Variants)

Torque - Measuring Device, Sensor Calibration Services

High-Precision Torque Calibration: Torque Sensors with Indicator / Calibrator, Torque Transducers with / without Indicator, Torque Meters, Rotary / Impact / Torque Gauges, and Torque Testers from 0.05 Nm to 3000 Nm.

WhatsApp Lab Desk
Calibration Capability (CMC)
0.05 Nm to 200 Nm: ± 0.12% | 200 Nm to 3000 Nm: ± 0.15%
Primary Master Equipment
Dead Weight Torque Calibration System of Lever Arm, Aluminium & Stainless Steel (SS) Dead Weights as per BS 7882.
Governing Standards
BS 7882, ISO/IEC 17025:2017, DIN 51309, EURAMET cg-14, IS/ISO 6789
Key Parameters & Applications
Clockwise & counter-clockwise torque, calibration sensitivity, linearity, hysteresis, zero return, repeatability, deflection under dead weight load.

Instruments & Parameters Covered (12)

Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).

Instrument / Parameter Calibration Range CMC (±) Master / Method
Torque Measuring Devices (Sensor / Transducer / Meter / Gauge / Tester) (0.05 Nm to 200 Nm) 0.05 Nm to 200 Nm ± 0.12 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Measuring Devices (Sensor / Transducer / Meter / Gauge / Tester) (200 Nm to 3000 Nm) 200 Nm to 3000 Nm ± 0.15 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Sensor with Indicator / Calibrator (0.05 Nm to 200 Nm) 0.05 Nm to 200 Nm ± 0.12 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Sensor with Indicator / Calibrator (200 Nm to 3000 Nm) 200 Nm to 3000 Nm ± 0.15 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Transducer with / without Indicator (0.05 Nm to 200 Nm) 0.05 Nm to 200 Nm ± 0.12 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Transducer with / without Indicator (200 Nm to 3000 Nm) 200 Nm to 3000 Nm ± 0.15 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Meter (0.05 Nm to 200 Nm) 0.05 Nm to 200 Nm ± 0.12 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Meter (200 Nm to 3000 Nm) 200 Nm to 3000 Nm ± 0.15 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Rotary / Impact / Torque Gauge (0.05 Nm to 200 Nm) 0.05 Nm to 200 Nm ± 0.12 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Rotary / Impact / Torque Gauge (200 Nm to 3000 Nm) 200 Nm to 3000 Nm ± 0.15 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Tester (0.05 Nm to 200 Nm) 0.05 Nm to 200 Nm ± 0.12 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882
Torque Tester (200 Nm to 3000 Nm) 200 Nm to 3000 Nm ± 0.15 % Using Dead Weight Torque Calibration System of Lever Arm, Aluminium / SS Dead Weights as per BS 7882

Frequently Asked Questions

Are Torque - Measuring Device, Sensor calibrations NABL accredited?

Yes. Our Torque - Measuring Device, Sensor laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.

Do you offer on-site Torque - Measuring Device, Sensor calibration at client plants?

Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Torque - Measuring Device, Sensor calibration, minimizing equipment downtime.

What is the standard turnaround time for calibration certificates?

Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.

How do I request a quotation for Torque - Measuring Device, Sensor?

Click the "Request a Quote" button on this page to pre-select Torque - Measuring Device, Sensor, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.

Explore Related Calibration Disciplines & Services

Industrial Turnkey AMC Plans • NABL Lab Setup Consultancy • ISO/IEC 17025:2017 Training Courses • Direct Lab Helpdesk
Call Lab WhatsApp