Biomedical Calibration Services

Defibrillator Analyzers, Patient Simulators, Electrosurgical Analyzers & Infusion Pump Testers.

WhatsApp Lab Desk
Calibration Capability (CMC)
Energy: ± 1.0% | Electrical safety leakage: ± 1.0% | Flow rate: ± 1.0%.
Primary Master Equipment
Fluke Biomedical Electrical Safety Analyzers, Multi-Parameter Patient Simulators (ECG/Respiration/NIBP/SpO2), Calibrated Precision Energy Loads.
Governing Standards
IEC 60601-1, IEC 62353, AAMI/ANSI standards.
Key Parameters & Applications
Delivered defibrillation energy (Joules), leakage current, NIBP pressure simulation, infusion flow rate & occlusion pressure.

Instruments & Parameters Covered (4)

Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).

Instrument / Parameter Calibration Range CMC (±) Master / Method
Defibrillator & Pacemaker Analyzers Energy discharge 1 to 360 Joules (Monophasic & Biphasic) ± 1.0% of reading Delivered energy accuracy into 50 Ω load, pulse waveform duration, peak current, sync time
Multi-Parameter Patient Simulators ECG (30–300 BPM), NIBP (0–300 mmHg), SpO2 (50–100%), Respiration, Temp ECG: ± 0.5% | NIBP: ± 0.5 mmHg | SpO2: ± 1% ECG amplitude & rate, blood pressure pulse waveform, optical absorption ratio (R-curve)
Electrosurgical Unit (ESU) Analyzers RF Power up to 400 W (Cut & Coagulation modes) ± 1.5% of reading High-frequency power output, crest factor, RF leakage currents to ground
Biomedical Electrical Safety Analyzers Leakage current 0.1 µA to 10 mA (Ground bond impedance 0.001 to 2.0 Ω) ± 1.0% of reading Earth leakage, chassis leakage, patient applied part leakage current (AC/DC)

Frequently Asked Questions

Are Biomedical calibrations NABL accredited?

Yes. Our Biomedical laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.

Do you offer on-site Biomedical calibration at client plants?

Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Biomedical calibration, minimizing equipment downtime.

What is the standard turnaround time for calibration certificates?

Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.

How do I request a quotation for Biomedical?

Click the "Request a Quote" button on this page to pre-select Biomedical, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.