Density - Viscosity Calibration Services
Alcoholometers, Baume Hydrometers, Brix Hydrometers, Density of Liquid, Density of Solid, Viscosity Flow Cups (Ford, DIN, ISO, Zahn, etc.), Lactometers, Sikes Hydrometers, Specific Gravity Hydrometers, Butyrometers, Twaddle Hydrometers, Dynamic Viscometers (Rotational, Krebs, Paddle, Brookfield).
Instruments & Parameters Covered (15)
Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).
| Instrument / Parameter | Calibration Range | CMC (±) | Master / Method |
|---|---|---|---|
| Alcoholometer (0 % v/v to 100 % v/v) | 0 % v/v to 100 % v/v | ± 1 % v/v | Using Standard Hydrometer and Liquid of known Densities as per IS 3608 |
| Baume Hydrometer (0 °Be to 70 °Be) | 0 °Be to 70 °Be | ± 0.1 °Be | Using Standard Hydrometer and Liquid of known Densities as per IS 1255 |
| Brix Hydrometer (0 °Brix to 100 °Brix) | 0 °Brix to 100 °Brix | ± 0.05 °Brix | Using Standard Hydrometer and Liquid of known Densities by Hydrostatic Weighing Method as per IS 7324 |
| Density of Liquid (0.6 g/ml to 2 g/ml) | 0.6 g/ml to 2 g/ml | ± 0.00004 g/ml | Using Semi Micro Balance of Range 220 g (Readability : 0.01 mg) with Calibrated Pycnometer as per IS 4730 & OIML G 14 |
| Density of Solid (0.5 g/ml to 15 g/ml) | 0.5 g/ml to 15 g/ml | ± 0.0031 g/ml | Using Semi Micro Balance of Range 220 g (Readability : 0.01 mg) with Density Determination Kit by Archimedes Principle as per OIML G14 |
| Ford Cup, DIN Cup, ISO Cup, Sheen Cup, B1 to B5 Cup, Dip Cup, Flow Cup, Shell Cup, Zahn Cup (Orifice Diameter: 1 mm to 7.12 mm) (17.05 cSt to 455.1 cSt) | 17.05 cSt to 455.1 cSt | ± 0.12 % to 0.17 % | Using Standard Viscosity Solutions, Timer, Temperature Indicator with Sensor by Comparison Method as per IS 3944 & ASTM D1200 |
| Lactometer (1 g/ml to 1.04 g/ml) | 1 g/ml to 1.04 g/ml | ± 0.04 g/ml | Using Standard Hydrometer and Liquid of known Densities by Hydrostatic Weighing Method as per IS 3104 |
| Sikes Hydrometer (0 °sk to 100 °sk) | 0 °sk to 100 °sk | ± 0.4 °sk | Using Standard Hydrometer and Liquid of known Densities by Hydrostatic Weighing Method as per IS 3608 |
| Specific Gravity / Relative Density - Density Hydrometer, Specific Gravity Hydrometer (0.6 g/ml to 2 g/ml) | 0.6 g/ml to 2 g/ml | ± 0.0003 g/ml | Using Hydrostatic Weighing Set Up, Weighing Balance with Underside Weighing Arrangement as per Cuckow Method, SIM MWG7/cg-03/v.00, OIML G14 |
| Butyrometers (L.C.: 0.05 % and coarser) (0 to 100 %) | 0 to 100 % | ± 0.023 % to 0.4 % | Using Standard Precision Balances (Readability: 0.01 mg) by Gravimetric Method as per ISO 488 :2008 & IS 1223:2001 |
| Twaddle Hydrometer (0 °Tw to 104 °Tw) | 0 °Tw to 104 °Tw | ± 0.25 °Tw | Using Standard Hydrometer and Liquid of known Densities by Hydrostatic Weighing Method as per IS 3104 |
| Viscosity (Dynamic Viscosity) - Rotational Viscometer, Krebs Viscometer, Paddle Viscometer, Brookfield Viscometer (1000 cP to 10000 cP) | 1000 cP to 10000 cP | ± 0.5 % | Using Calibrated Newtonian Liquids by Comparison Method as per ISO 2555 & ISO 1652 |
| Viscosity (Dynamic Viscosity) - Rotational Viscometer, Krebs Viscometer, Paddle Viscometer, Brookfield Viscometer (10000 cP to 94960 cP) | 10000 cP to 94960 cP | ± 0.5 % | Using Calibrated Newtonian Liquids by Comparison Method as per ISO 2555 & ISO 1652 |
| Viscosity (Dynamic Viscosity) - Rotational Viscometer, Krebs Viscometer, Paddle Viscometer, Brookfield Viscometer (500 cP to 1000 cP) | 500 cP to 1000 cP | ± 0.5 % | Using Calibrated Newtonian Liquids by Comparison Method as per ISO 2555 & ISO 1652 |
| Viscosity (Dynamic Viscosity) - Rotational Viscometer, Krebs Viscometer, Paddle Viscometer, Brookfield Viscometer (39.82 cP to 500 cP) | 39.82 cP to 500 cP | ± 0.5 % | Using Calibrated Newtonian Liquids by Comparison Method as per ISO 2555 & ISO 1652 |
Frequently Asked Questions
Are Density - Viscosity calibrations NABL accredited?
Yes. Our Density - Viscosity laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.
Do you offer on-site Density - Viscosity calibration at client plants?
Calibration for Density - Viscosity is performed inside our environmentally controlled permanent metrology facility in Madipakkam, Chennai, to preserve measurement stability and CMC accuracy.
What is the standard turnaround time for calibration certificates?
Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.
How do I request a quotation for Density - Viscosity?
Click the "Request a Quote" button on this page to pre-select Density - Viscosity, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.